[TANAKA]AKV-202自动运动粘度试验仪                                                                                                                                                                                                                                                                                                                                            
[TANAKA]AKV-202自动运动粘度试验仪

 

 

自动运动粘度试验仪

AKV-202

 

Model AKV-202 has been designed for automatic determination of KINEMATIC VISCOSITY. Once a specimen is set the series of processes including timing, cleaning/drying of viscometer tube, and reporting are fully automated. AKV-202 is an economical bench-top system, which saves not only the technician’s time but also valuable laboratory floor space and budget.

AKV-202自动运动粘度测试仪是用于自动测定石油产品运动粘度的试验装置。只需要简单设定就可以自动完成从样品进样,样品测试,打印试验结果,到清洗并干燥粘度计的一系列工作。AKV-202是一个设计精巧的台式试验装置,占用空间小,经济适用。试验过程完全自动,既避免了人为因素的干扰,也节约了试验操作人员大量的时间。

 

WIDE RANGE OF SAMPLES: Wide range of Kinematic Viscosity(KV) can be covered with the modified Lanz-Zeitfuchs viscometers. The reverse flow viscometer covers both transparent and opaque samples and also eliminates drainage error.

粘度测定范围广:采用了改进型兰兹-斯特福斯粘度计,可以测定各种透明和不透明试样。

 

AUTOMATIC MEASUREMNT: Timing, sample draining, viscometer cleaning/drying, calculating/reporting are automated, saving the time of the experienced hands and improving repeatability.

自动测试:计时,自动进样和清洗粘度计,计算结果并打印报告的过程全自动进行,可节省大量时间,无须人员的手工操作和熟练度,试验结果可靠和有重复性。

 

COMPACT DESIGN: The two-viscometers/one-bath system is housed in a compact housing that is small enough to install on a lab bench.

紧凑的设计:台式试验仪器,封闭式恒温浴槽,放置于实验台上,可同时进行2支(同组或分组的)运动粘度测试

 

EASY VISCOMETER REPLACEMENT: Viscometer is mounted to a viscometer holder and the viscometer/ holder assembly can be removed from the bath at ease, which assures easy viscometer replacement.

粘度计用独立的支架安装,可以简单的取出和更换

 

OVERFLOW: The viscometer has a provision of overflow, which eliminates errors from inconsistency in sampling volume as well as thermal expansion of the sample.

改进型兰兹-斯特福斯粘度计可有效的减少热胀冷缩对试验的影响

 

VERSATILE CLEANING/DRYING SYSTEM: Two tanks are provided for cleaning and drying the viscometers, which allows quick and efficient cleaning/drying by selecting the best chemicals for the sample.

独有的清洗系统:可选用2种不同的化学清洗液对粘度计进行清洗,清洗效果好,无残留,清洗完成后还可自动吹风干燥粘度计。

 

 

 

TANAKA Kinematic Viscosity Measuring System, model AKV-202

TYPE

Bench top automatic KV measuring system with 2 viscometers in 1 bath

自动运动粘度测试,封闭式恒温浴槽,2支粘度计

 

RELATED STANDARDS: (适用标准)

ISO 3104, ASTM D445, IP71, GB/T 265 etc.

 

VISCOMETERS: (粘度计类型)

Modified Lanz-Zeitfuchs viscometers 改进型兰兹-斯特福斯粘度计

 

MEASURING RANGE: (测试范围)

10,000 mm2/s for automatic operation. (Range depends on viscometer.)

10,000 mm2/s 根据下表选择不同的粘度计

 

MENISCUS DETECTION: (检测方式)

By photo-electric devices with fiber optics

光纤传导 + 光电检测传感器

 

TIMING: (时间计数)

0.00 - 999.99 sec 0.00 - 999.99 秒,精确到2位小数)

 

BATH: (恒温浴槽)

Bath: Stainless Steel bath with drain, 18 liters Heater: Sheathed heaters, 0.59kW x2 Lighting: Fluorescent light, 6W

全不锈钢恒温浴槽,约 18,内置加热装置(0.59kW x2),后置荧光照明灯(6W

Medium:Water(distilled or ion exchanged)for < 75,

75以下时可用蒸馏水或去离子水作为恒温介质

Colorless/transparent silicon oil (with PMCC flash point of 190 at minimum and KV of 10-20mm2/s) for >= 75 .

75以上时用无色透明的硅油作为恒温介质(要求PMCC闭口闪点大于190 ,运动粘度为10-20mm2/s

 

BATH TEMPERATURE CONTROLLER: (浴槽恒温控制)

Temp:  Preset at 6 points.  Preset point can be set at any temp between 20 and 100. Precision:  +/-0.01 Controller: PID control by a micro-processor

20100预设6点,PID控温精度±0.01


 

CLEANING/DRYING VISCOMETERS: (粘度计的清洗和干燥)

An automatic cycle consisting of draining sample, injecting chemicals, and drying with air. By vacuum.

在每次测试后,按程序注入清洗溶剂,进行多次负压牵引清洗,排出废液后进行吹风干燥粘度计

Chemicals:  BTX for cleaning, Ethanol Bath Temp <80oCfor drying. (Ether or Ketone can not be used)

清洗液:在恒温浴槽温度小于80的情况下,可选用BTX (对二甲苯)和乙醇作为清洗溶剂(不可使用燃点较低的醚类或酮类化学品)

Fume:  Fume to be exhausted through trap and hose to outside

废气可通过软管引出室外排放或用收集瓶收集。

 

DISPLAY: (显示输出)

Test parameters, status, trouble, etc. displayed on fluorescence display module

荧光数显:测试参数,测试结果,出错警示,等。

 

PRINTER: (打印机)

Thermal printer, 58mm of paper width 热敏打印机,纸宽 58mm

 

COMPUTER OUTPUT: (计算机输出)

RS-232C, 1 channel  RS-232C标准接口 1

 

SAFETY: (安全保护)

Alarms for gas, bath medium level, & bath overheat 气体保护,液位保护,温度保护

 

POWER REQUIREMENTS: (电源需求)

100, 120, 220 or 240VAC, 2KW

 

DIMENSION & WEIGHT: (体积/重量)

530mmW x 560mmD x 930mmH, 75kg

 

ORDERING INFORMATION:  (定购要求)

STANDARD ACCESSORIES 标准附件

 

1.Viscometers(*) 粘度计

2

2.Viscometer holders粘度计支架

2

3.Beaker样品杯

5

4.Clips for spherical joints 球面夹箍

4

5.Printer roll papers打印纸

1

6.Duct hose 连接软管

5m

7.Cleaning solvent tanks 清洗液瓶

2

8.Overflow tank 废液瓶

1

8.Drain jars 排液桶

2

9.Exhaust gas trap  废气冷凝收集瓶

1

 

*Select 2 viscometers from the table below: (按下表范围任选2支粘度计)

Tanaka Viscometer No.

KV range  mm2/s

TLZ 1

0.75 ¬3.75

TLZ 2

2 -10

TLZ 3

6 -30

TLZ 4

20 -100

TLZ 5

60 -300

TLZ 6

200 -1,000

TLZ 7

600 -3,000

TLZ 8

2,000 -10,000

 

 

OPTIONAL ACCESSORIES: (推荐附件)

1.Thermometers for bath: for 30, 40, 50, 80 &100

检验用温度计,30, 40, 50, 80 &100

 

2.Chiller: Used when differential between room temp. and bath temp. is less than 15 . Thomas TRL-108H (Made in Japan) or Julabo F200 (Made in Germany) is recommended.

制冷源:试验要求和室温环境相差15以上时,需要加配外接制冷源。

推荐:·TRL-108H (日本田中)   ·Julabo F200(德国)

 

3.Silicon oil for bath (17 kg) when bath temperature  is set 80 or higher.

无色高温硅油,用于80 以上的运动粘度试验,17 kg

 

                                                                                                                                                                                                                                                                                                                                           
样本下载
[暂无下载]
技术标准

GB 265GB/T 11137ASTM D445

  
ASTM D445-2006 透明和不透明液体运动粘度的测试方法(包括动态粘度的计算)
GB 265-88 石油产品运动粘度测定法和动力粘度计算法
GB/T 11137-1989 深色石油产品运动粘度测定法(逆流法) 和动力粘度计算法
GB/T 22235-2008 液体黏度的测定
JJG 154-2012 标准毛细管黏度计
JJG 155-1991 工作毛细管粘度计检定规程
JJG 155-2016 工作毛细管黏度计检定规程
JJG 2016-1987 粘度计量器具检定系统
NB/SH/T 0912-2015 发动机台架试验油100℃运动黏度测定法
 

实例应用
 

相关仪器
1. KV-3型运动粘度恒温槽
2. KV-4型运动粘度恒温槽
3. KV-L12型低温运动粘度恒温槽
4. 全新双浴全自动运动粘度测定仪CAV4.2(单机双恒温浴双粘度计)
5. 玻璃毛细管粘度计_Cannon-Fenske 坎农-芬斯克毛细管粘度计
6. 玻璃毛细管黏度计 (Glass Capillary Viscometers)
闪点-闪点仪-闭口闪点-开口闪点-开闭口闪点-开口杯-闭口杯-宾斯基马丁-宾斯基·马丁--克利夫兰-泰克杯-双联杯-多联杯 -flash point-Pensky-Martens closed cup -卡尔·费休-卡-费休-卡费休-卡氏-卡尔菲休-水分测定仪-电位滴定-电位滴定仪-密度计-密度仪-折射率测定仪-折射率计-折光计-折光仪-白度计-白度仪-酸度计-盐分测定-糖度仪-糖度仪-倾点-浊点,冷滤点,苯胺点-残炭-微量残炭-微量法-酸值-碱值-溴值-溴指数-硫醇硫-碱性氮-盐含量测定仪-氧化安定性-旋转氧弹-四球法-抗磨极压-锥入度-针入度-滴点-熔点-滴熔法-冷曲线法-软化点-沥青软化点
黑球计-湿球计-温度计-热环境-环境分析-热环境分析-WBGT指数-PMV指数-PPD指数-劳动安全卫生- PH电极-指示电极-参比电极-离子选择电极-Potentiometric Titrator-Density-Specific Gravity Meter 
石油-石油产品-石油仪器-鸿帆-旭风-德屹-KEM-PSS-baidu-google 根据需要,公司可未经预告对仪器的规格和外形进行更改,望予以谅解为盼。
 
Copyright © 2012-2020. All Rights Reserved.
上海旭风科学仪器有限公司 版权所有
电话:021 66581985/63172460 传真:021 66581986
地址:上海市延长中路783 新华园C座4005室 邮编:200072