[型号停产][TANAKA]AAP-5自动苯胺点测试仪_上海旭风科学仪器有限公司
自主生产销售自动化油品分析仪器,日本京都电子KEM中国区代理
上海旭风科学仪器有限公司
 网站首页  联系我们  网站地图
自主生产销售自动化油品分析仪器,日本京都电子KEM中国区代理
 
产品列表
石油化工分析仪器
日本KEM京都电子仪器
美国CANNON凯能仪器
专项测试仪器
标准物质
友情链接
---
[型号停产][TANAKA]AAP-5自动苯胺点测试仪
----
详信信息
[型号停产][TANAKA]AAP-5自动苯胺点测试仪                                                                                                                                                                                                                                                                                                                                            
[型号停产][TANAKA]AAP-5自动苯胺点测试仪

自动苯胺点测试仪
AAP-5


AAP-5 automates the aniline point test of petroleum products. As found in other Tanaka petroleum testers, ease of use and high reliability have been further sought when designing this latest version of the automated aniline point tester. Model AAP-5 is capable of covering a wide range of samples including transparent samples as well as dark/opaque samples.
AAP-5自动苯胺点测试仪是“田中科学机器制作株式会社”多年石油产品自动测试仪专业生产的丰富经验积累,用高新技术开发出来的最新产品,操作简单,测定高效,结果可靠。相比于同类产品,AAP-5有着更宽泛的测试范围,同时适用于测试透明和不透明(深色/黑色)的样品。

DARK/OPAQUE SAMPLES: The use of special infrared detector gives the instrument it’s ability to see through dark/opaque samples such as residual fuels with up to 8.0 on the ASTM Color Scale. 测试范围广:专用的红外线光电检测,无论是透明或是不透明试样(ASTM色小于8.0),都可测试。


USER-FRIENDLY MEASURING CELL: The measuring cell can be easily removed and placed on an analytical balance for weighing viscous samples that are solid at ambient temperature. Water jacketed measuring cells are also available as an option for sub-ambient temperature.
为便于称量常温固态试样,测定容器分为固定的上部和可脱卸的下部两部分组成,可将下部容器卸下采样和称量,十分方便。样品杯上的环绕水浴设计,可外接加热/制冷源,保持样品的温度特性。


EASY OPERATION: Just sample the specimen and aniline, enter the expected aniline point,and press the START key; all the rest of the test procedures such as heating, cooling and aniline point detection are performed automatically. The operator has an option to report the result after either single determination or multiple determinations.
操作简单:只要加样和设定预期苯胺点后,按下“START”键,仪器就能自动进行样品加热,样品冷却,测试苯胺点,连续多次重复试验等一系列动作。试验人员只需要直接读出最终试验结果就可以了。
 

EASIER AND SAFER ANILINE HANDLING: For years, handling of the toxic aniline has been considered a hazardous operation. A bottle top dispenser can be connected to the measuring cell for directly delivering aniline without a manual pipetting operation. Upon completing a test, discharge the aniline mixture from the bottom of the measuring cell, pour a cleaning agent, turn on the stirrer, and discharge the cleaning agent. The measuring cell can be cleaned without disassembling it, which makes the cleaning easier and safer.
仪器配合自动进样器(用户自配)配合使用。用自动进样器来处理苯胺,可避免直接处理有毒的化学品苯胺对人体造成伤害。测试完成,可以直接用放液阀直接排出废液,另行处理。而排出废液后的样品杯清洗也很方便,并不需要取下样品杯手工清洗。配合洗液和仪器本身的加热功能,即便是重油等不易清洗的试样也能方便有效地清洗干净。


DATA HANDLING: The unit is equipped to store up to 20 successive test results and export to an optional printer or to a LIMS through an RS232 port. 记录储存最后20次试验结果,可外接打印机输出或通过RS232与自动联用分析系统连接,联网操作。


COMPACT DESIGN: Like the popular Tanaka flash point testers, AAP-5 consists of a test head unit and a separate control unit. The test head unit is small enough to be remotely operated inside of a fume hood. 同“田中科学机器制作株式会社”的闪点测试系列仪器一样,AAP-5可分为“测定部”和“控制部”2个部分,可以上下叠置,占用面积很少,也便于搬动。

 

TANAKA Automated Aniline Point Tester, model AAP-5

SPECIFICATIONS:
CONFORMING STANDARDS: (适用标准)
ISO 2977, ASTM D611, GB/T 262 etc.

SAMPLES:
Transparent or opaque/dark (<8.0 on ASTM color scale)
测试范围广。同时适用于透明和不透明(深色/黑色)的样品。(要求ASTM色小于8.0)

MEASURING RANGE: (测量范围)
Ambient to 170℃ (338℉) For sub-ambient, use the optional water jacketed measuring cell and a cryostat.
室温-170℃ (338℉),也可配合专用的“低温测试杯”和外接冷源进行低温苯胺点的测量

TEMPERATURE SENSOR: (温度传感器)
PT-100 in stainless steel sheath 带不绣钢护套的PT-100铂电阻

ANILINE POINT DETECTOR: (苯胺点检测)
Photo-electric cell, with special detection circuitry MEASURING CELL: Modified U-Tube type. Vacuum jacketed glass cell with TFE stopcock at the bottom for drainage.
配合特制的分离式“U”字样品杯(真空护套,带排样阀)取样、称量、检测兼用,光电检测。

DISPLAY: (显示)
Vacuum fluorescent display(VFD) 荧光显示屏(VFD)

HEATER: (加热)
Immersion heater in stainless steel sheath: 20W 浸没式不绣钢加热器,20W

SEQUENSE CONTROL: 程序控制
By an on-board microcomputer 内置微处理器

TEST MODE:
Single or repeated determinations (2 kinds, average is reported to nearest 0.05℃)

DATA OUTPUT: (数据输出)
RS-232C  1 channel  (for PC or Optional Printer) RS-232C 接口,1,可连接电脑或打印机

SAFETY MECHANISM: (安全保护)
Automatically shuts off and the problem is reported by buzzer and display, in case:
在下列情况下,仪器自动停止试验,连续报警并显示出错信息:

(a) EAP+10℃ or at 170℃ is reached, 超过预期苯胺点10℃时,或到170℃还没测出苯胺点时,
(b) Temperature sensor is found defective, 温度传感器失效时
(c) Light projector or receiver is found defective光电检测组件失效时
(d) Control computer runs away (no display) 微处理器出错(无显示)

DIMENSION & WEIGHT: (体积/重量)
控制部Control unit: 230W x 455D x 105H (mm), 7.0kg
测试部Test unit: 230W x 350D x 580H (mm), 8.0kg

INSTALLATION SITE: 环境要求
Ambient temperature: 0 to 40℃ RH: Less than 90%(no condensation)
室温0~40℃/ 湿度90%以下(无凝结)

POWER SUPPLY: (电源要求)
AC100/120V or 220/240V 50/60Hz (set at the factory)出厂设定,定购前要说明
0.1kW(max.)  最大功率0.1kW

ORDERING INFORMATION: 
STANDARD ACCESSORIES: (标准附件)

1     Power Connecting Cable, 0.6m电源连接线

1pc

2     Signal Connecting Cable, 0.6m数据连接线

1pc

3     AC Power Cord, 3.0m (<125V) or 2.5m (>200V) 电源线

1pc

4     Measuring Cell Stand 标准样品杯组件(上下一组)

1pc

5     Hexagonal Wrench 6角扳手,拆卸工具)

1pc

6     Spare Glass Tube Fuse (3A) 保险丝

1pc

7     Instruction Manual 使用说明书

1pc

OPIONAL ACCESSORIES: (选购件1)
Water Jacketed Measuring Cell, Lower低温测试样品杯,低温测试专用
Power Connecting Cable, 3m加长电源连接线
Signal Connecting Cable, 3m 加长数据连接线
Built-in Clock Board (for time/date verification) 时钟板(提供日期/时间)
Printer, BS2-80TS 打印机  (推荐配合时钟板使用,可直接打印日期/时间)
(we recommend that optional Built-in Clock Board be purchased with this Printer)

SUGGESTED SPARES FOR 2 YEARS: (选购件2,2年维护)

1.    Flexible Shaft 搅拌软轴

2pcs 

2.    Measuring Cell, Upper, 2-Inlet Type样品杯组件(上部,2口型)

1pc

3.    Measuring Cell. Lower样品杯组件(下部)

1pc

4.    Temperature Sensor 温度传感器

1pc

5.    Heater Assembly 加热器组件

1pc

6.    Glass Tube Fuse 3A 保险丝

1pc



TFE tubing connected to measuring cell for direct connection to bottle-top dispenser for a safer aniline handling. TFE tubing and fitting not provided with AAP-5.

我们推荐选用(2口型的样品杯上部组件)和自动进样器(用户自配)配合使用。用自动进样器来处理苯胺,可避免直接处理有毒的化学品苯胺对人体造成伤害。
(2口型的样品杯上部组件)和四氟乙烯(TFE)连接套件在选购件中都有提供。

                                                                                                                                                                                                                                                                                                                                           
样本下载
[暂无下载]
技术标准
  
ASTM D611-12 石油产品和烃类溶剂的混合苯胺点和苯胺点的试验方法
ASTM D611-2004 石油产品和烃类溶剂的混合苯胺点和苯胺点的试验方法
GB 262-88 石油产品苯胺点测定法
GB/T 262-2010 石油产品和烃类溶剂苯胺点和混合苯胺点测定法
ISO 2977-1997 石油产品和烃类溶剂.苯胺点和混合苯胺点的测定
 

实例应用
 

相关仪器
1. AP-L1型自动苯胺点测定仪
2. AP-L2型自动低温苯胺点测定仪
3. AP-L1s_自动苯胺点测定仪[外贸版]
闪点-闪点仪-闭口闪点-开口闪点-开闭口闪点-开口杯-闭口杯-宾斯基马丁-宾斯基·马丁--克利夫兰-泰克杯-双联杯-多联杯 -flash point-Pensky-Martens closed cup -卡尔·费休-卡-费休-卡费休-卡氏-卡尔菲休-水分测定仪-电位滴定-电位滴定仪-密度计-密度仪-折射率测定仪-折射率计-折光计-折光仪-白度计-白度仪-酸度计-盐分测定-糖度仪-糖度仪-倾点-浊点,冷滤点,苯胺点-残炭-微量残炭-微量法-酸值-碱值-溴值-溴指数-硫醇硫-碱性氮-盐含量测定仪-氧化安定性-旋转氧弹-四球法-抗磨极压-锥入度-针入度-滴点-熔点-滴熔法-冷曲线法-软化点-沥青软化点
黑球计-湿球计-温度计-热环境-环境分析-热环境分析-WBGT指数-PMV指数-PPD指数-劳动安全卫生- PH电极-指示电极-参比电极-离子选择电极-Potentiometric Titrator-Density-Specific Gravity Meter 
石油-石油产品-石油仪器-鸿帆-旭风-德屹-KEM-PSS-baidu-google 根据需要,公司可未经预告对仪器的规格和外形进行更改,望予以谅解为盼。
 
Copyright © 2012-2020. All Rights Reserved.
上海旭风科学仪器有限公司 版权所有
电话:021 66581985/63172460 传真:021 66581986
地址:上海市延长中路783 新华园C座4005室 邮编:200072